Standard Parameters
• ECG
• SpO2
• NIBP
• Respiration
• Temperature
• Pulse
Feature Set
• 12.1” Color TFT Display with Maximum 7 Waveforms
• Optional Multi-language Operation Menu
• Support Patient Information Input
• 12-lead ECG Waveforms Display
• up to 10 Minutes ECG Replay Capacity
• 12.1” Color TFT Display with Maximum 7 Waveforms
• Two Optional Display Method: Refreshing and Rolling
• Various Waveforms can be Flexibly Grouped and Changed in Color
• Power Fail Safeground Function, Capable of Storing Previous Monitoring Data
• Individual Digital Module Structure, Convenient for Maintenance and Upgrade
• Digital SpO2 Technique, Precise Measurement for Low Perfusion and Finger Shaking
• Protection Against Interference from Defibrillation and High-frequency Electrotome
• Intelligent Voice/Light Alarms Accurately Transmit Diseases
• Adult/Pediatric/Neonatal measurement modes
• Compatible with Central Monitoring System, Support Wireless Connection
Standard Accessories
1 x ECG Cable & Wires, 1 x pack Electrodes, 1 x Adult Digital SpO2 Probe, 1 x Adult NIBP Cuff, 1 x TEMP Probe,
1 x Built-in Battery, 1 x Ground Line
Optional Accessories
IBP, EtCO2, VCG, Build-in Recorder,Special Accessories for Neonatal and Pediatric Patient
Technical Specifications
HR
Measure Range: 0-250bpm
Accuracy: ±2bpm
RESP
Measure Range: 0-100%
Accuracy: ±2bpm
TEMP
Range: 25°C-45°C
Accuracy: ±0.2°C
ECG
Input: 12-lead
Lead Selection: 12-lead Automatic Shift
Sweep Speed: 25mm/s 50mm/s
Sensitivity: 5mm/mv, 10mm/v, 20mm/v
Noninvasive Blood Pressure
Measurement Technique: Automatic Oscillometric
Measurement Range:
Adult: 20-245mmHG
Pediatric: 20-135mmHG
Accuracy: ±5 mmHG
Resolution: 1 mmHG
Measure Mode: Manual/Automatic/Continuous
Range: Adult/Pediatric/Neonatal
Protection: Double Security Protection
Alarm
Range: Adjustable from Lower to Upper Limit
Cause: Irregular Indication
Indications: Audible and Visual Dual Indications
Safety
This device is designed and manufactured by strictly complying with the following standards :
• CE Standard : Directive 93/42/EEC on Medical Devices.
• IEC60601 Related Standards
Power Requirement
Voltage: AC100-240V 50HZ/60HZ
IBP (Optional)
Channel: Double Channel
Pressure Sensor: Sensitivity: 5V/mmHg
Pressure Name: ART, PA, CVP, RAR, LAP, ICP
CO2 (Optional)
Measure Mode: Bypass Mode
Measure Parameter: CO2 Breathe-out, Airway HR
Recorder (Optional)
Type: 50mm Thermal Recorder (Printer)
Port: Standard Parallel
Printing Setting: Manual Recording, Alarm Recording, Time Recording, Real-time Recording
Weight
4.5kg
Dimension
350x150x330mm
|