Multi-parameter Maternal/Fetal Monitor

av-9005_ph

Model:AV-9005



Standard Parameters:

• FHR

• TOCO

• FM

• ECG

• SpO2

• NIBP

• Respiration

• Temperature

• Pulse Rate

 

 

 

 

 

 

 

Overview

  

 • 12.1” TFT touch folding up LCD.

 • Light Weight and Portable, Easy Operation Mode.

 • Build-in High-capacity Battery, Up to 5 Hours Working Time.

 • Maximum 11 Hours Storage and Replay of Fetal/Maternal Monitoring Data.

 • Optional Built-in Recorder, Able to Print or Store Waveforms and Monitoring Status at Real Time.

 • Advanced Digital Signal Processing (DSP) Technique is Applied for Real-time Calculation and Mode Identification.

 • High-sensitive Probe, Excellent Signal/Noise Ratio and Accurate Calculation Enable to Monitor Fetus More Safely.

 • Individual Digital Module Structure, Convenient for Maintenance and Upgrade.

 • Digital SpO2 Technique, Precise Measurement for Low Perfusion and Finger Shaking.

 • Protection Against Interference from Defibrillation and High-frequency Electrotome.

 • Intellectualized Voice/Light Alarms Accurately Transmit Diseases.

 • Adult/Pediatric/Neonatal measurement modes.

 • Network Capability, Compatible with Obstetric Central Monitoring System.

 • Standard Configuration: ECG Cable & Wires, Adult Digital SpO2 Probe, Adult NIBP Cuff, TEMP Probe, Pack Electrodes, Built-in Battery, Three–in–One Probe (FHR, TOCO, FM), Biding Belt, Transmission Gel.

 • Optional Accessories: Twin, Built-in Recorder, Special Accessories for Neonatal and Pediatric Patient.

 

Specifications

  

Display

12.1” TFT touch folding up LCD.

TOCO

 

Range

0-100 pressure units

Nonlinear Tolerance for Measurement

±5%

FHR

 

Probe

9 chips, wide wave packet, Pulse wave

Strength of ultrasonic wave

less than 3mW/cm2

Working Frequency

1.0MHz or 2.2MHz

Signal processing

special digital signal processing (DSP) and mode identification

Range

10-240bpm

FM

 

Counting Method

Manual

ECG

 

Number of Leads

5

Lead Selection

I, II, III, avR, avL, avF, and V1~V6

Gain Selection

x0.5, x1, x2, and x4

Sweep Speed

12.5mm/s, 25mm/s, and 50mm/s

HR display

20~250 bpm

Precision

±1bpm

NIBP

 

Measurement Technique

Automatic Oscillometric

Measurement Range

 

- Adult

20-245mmHg

- Pediatric

20-135 0mmHg

Accuracy

±5 mmHg

Resolution

1 mmHg

Measure Mode

Manual /Automatic

Automatic Measuring Interval

3-240min

Temperature

 

Range

20°C-45°C

Accuracy

±0.1°C

Resolution

0.1°C

Pulse

 

Range

20-250bpm

Accuracy

±1bpm

Resolution

1bpm

SpO2

 

Range

70-100%

Resolution

1%

Accuracy

±1%

Respiration

 

Range

0-60bpm

Accuracy

±1bpm

Resolution

1bpm

Alarm

 

Range

Adjustable from Lower to Upper Limit

Cause

Irregular Indication

Indication

Audible and Visual Dual Indication

Power Requirement

 

Voltage

AC100-240V 50HZ/60HZ

Printer (Optional)

 

Type

Built-in 50mm Thermal Printer

Port

Standard Parallel

Weight

6.3kg

Dimension

320mm×280mm×170mm